Series 20 Model MLV22 (REVERSE POLARITY)


2-Way Normally Closed Valve


This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited, as it only uses power during latching and un-latching. It is also valuable in equipment where coil heating, due to continuous application of power, is undesirable. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials.

Neutral (−) a. Pulse Yellow lead to Positive (+) to latch   b. Pulse Blue lead to Positive (+) to un-latch  

Positive (+) a. Pulse Yellow lead to Neutral (−) to un-latch   b. Pulse Blue lead to Neutral (−) to latch  

VALVE SPECIFICATIONS

Valve specifications — Series 20 Model MLV22 (REVERSE POLARITY)
MAX. OPER.    VALVE NUMBER
 
PRESS. DIFF.ORIFICE SIZECV FACTOR  DIN COIL (2 TERMINALS WITH GROUND)2 WIRE COIL
DC    1/8 NPT PORTS1/4 NPT PORTS1/8 NPT PORTS1/4 NPT PORTS
10001/32.024  22G7DELM-∆22G9DELM-∆22G7DGLM-∆22G9DGLM-∆
5003/64.052  22H7DELM-∆22H9DELM-∆22H7DGLM-∆22H9DGLM-∆
4001/16.095  22J7DELM-∆22J9DELM-∆22J7DGLM-∆22J9DGLM-∆
2503/32.156  22K7DELM-∆22K9DELM-∆22K7DGLM-∆22K9DGLM-∆
2001/8.214  22N7DELM-∆22N9DELM-∆22N7DGLM-∆22N9DGLM-∆
1505/32.404  22O7DELM-∆22O9DELM-∆22O7DGLM-∆22O9DGLM-∆
503/16.500  22P7DELM-∆22P9DELM-∆22P7DGLM-∆22P9DGLM-∆
401/4.700  22R7DELM-∆22R9DELM-∆22R7DGLM-∆22R9DGLM-∆

 

Operating Conditions

Media
Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Electrical Characteristics

Coil Voltage
6, 9, 12, 24/DC
Nominal Power
DC — 10.0 Watts
Coil Construction
Molded Class B with DIN 43650 Form A Connector (Std.), Leadwires (Opt.) For your convenience we have the female DIN style mating connector No. 20-198** available for an additional fee.*
Typical Response Time on Air
Approximate 50 millisecond pulse to energize and de-energize.
Operating Speed
Up to 600 CPM

Mechanical Characteristics

Body
Stainless Steel (Std.) or Brass (Opt.)
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/8” and 1/4” NPT (other ports available).*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.2 lb average
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.

Series 20 Model 22 Magnetic Latching

Technical drawing — MODEL 22 1/4-18 NPT 2WNC MAGNETIC LATCHING COIL DIN STYLE COIL
MODEL 22 1/4-18 NPT 2WNC MAGNETIC LATCHING COIL DIN STYLE COIL
Technical drawing — MODEL 22 1/8-27 NPT 2WNC MAGNETIC LATCHING COIL DIN STYLE COIL
MODEL 22 1/8-27 NPT 2WNC MAGNETIC LATCHING COIL DIN STYLE COIL
Technical drawing — MODEL 22 METERING 2WNC MAGNETIC LATCHING COIL DIN STYLE COIL
MODEL 22 METERING 2WNC MAGNETIC LATCHING COIL DIN STYLE COIL
Technical drawing — MODEL 22 1/4-18 NPT 2WNC MAGNETIC LATCHING COIL WITH LEADS
MODEL 22 1/4-18 NPT 2WNC MAGNETIC LATCHING COIL WITH LEADS
Technical drawing — MODEL 22 1/8-27 NPT 2WNC MAGNETIC LATCHING COIL WITH LEADS
MODEL 22 1/8-27 NPT 2WNC MAGNETIC LATCHING COIL WITH LEADS
Technical drawing — MODEL 22 METERING 2WNC MAGNETIC LATCHING COIL WITH LEADS
MODEL 22 METERING 2WNC MAGNETIC LATCHING COIL WITH LEADS
Nomenclature, all valve series except 58

Cv Flow Formulae

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM
PSI
GPM
Calculate Cv
GPM
PSI
Calculate P1−P2
GPM
PSI

Gas Flow P2 > 53% of P1 (subsonic)

Calculate Flow in CFM
PSIA
PSIA
°R
CFM
Calculate Cv
CFM
PSIA
PSIA
°R
Calculate P1 (approx.)
CFM
PSIA
°R
PSIA
Calculate P2 (approx.)
CFM
PSIA
°R
PSIA

Gas Flow P2 < 53% of P1 (sonic)

Calculate Flow in CFM
PSIA
°R
CFM
Calculate Cv
CFM
PSIA
°R
Calculate P1
CFM
°R
PSIA

DISCLAIMER: Gas flow is only an approximation using Cv.