2-Way Normally Closed Valve
This valve is Class 1 DIV II CSA Recognized. This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited. It is also valuable in equipment where coil heating, due to continuous application of power, is undesirable. Air, water and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require other seal materials.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | 4 PIN LATCHING DIN COIL | 3 WIRE LEADWIRE VALVE NUMBER | ||||
|---|---|---|---|---|---|---|---|---|
| DC | 1/8 NPT PORT | 1/4 NPT Port | 1/8 NPT PORTS | 1/4 NPT PORTS | ||||
| 500 | 1/32 | .024 | 22G7D4LM-∆ | 22G9D4LM-∆ | 22G7D3LM-∆ | 22G9D3LM-∆ | ||
| 500 | 3/64 | .052 | 22H7D4LM-∆ | 22H9D4LM-∆ | 22H7D3LM-∆ | 22H9D3LM-∆ | ||
| 215 | 1/16 | .095 | 22J7D4LM-∆ | 22J9D4LM-∆ | 22J7D3LM-∆ | 22J9D3LM-∆ | ||
| 150 | 3/32 | .156 | 22K7D4LM-∆ | 22K9D4LM-∆ | 22K7D3LM-∆ | 22K9D3LM-∆ | ||
| 120 | 1/8 | .214 | 22N7D4LM-∆ | 22N9D4LM-∆ | 22N7D3LM-∆ | 22N9D3LM-∆ | ||
| 80 | 5/32 | .404 | 22O7D4LM-∆ | 22O9D4LM-∆ | 22O7D3LM-∆ | 22O9D3LM-∆ | ||
| 35 | 3/16 | .500 | 22P7D4LM-∆ | 22P9D4LM-∆ | 22P7D3LM-∆ | 22P9D3LM-∆ | ||
| 25 | 1/4 | .700 | 22R7D4LM-∆ | 22R9D4LM-∆ | 22R7D3LM-∆ | 22R9D3LM-∆ | ||
Ordering Information:
Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM
When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (151J2XGM 120/60) repair pack (K1513X AC)
When ordering operators add the letter "O" to the front of the valve number, replace body port number with the letter "D": example: operator (O151JDXGM 120/60)
Operating Conditions
- Media
- Air, water, and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require other seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
- Valve Temperature Range
- Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
- Maximum Operating Pressure Differentials
- See table above.
- Burst Pressure
- 5,000 PSI
- Leakage
- Bubble tight for standard valves.
- Vacuum
- To 5 Microns*
Electrical Characteristics
- Coil Voltage
- 6, 9, 12, 24/DC
- Nominal Power
- 8.0 Watts
- Coil Construction
- Molded Class B with three - 24” leadwires
- Typical Response Time on Air
- Approximate 50 millisecond pulse to energize and de-energize.
- Operating Speed
- Up to 600 CPM
- Duty Cycle
- Continuous
Mechanical Characteristics
- Body
- Stainless Steel
- Internal Components
- Stainless Steel
- Elastomers
- Nitrile (Buna) standard. FKM, EPDM, Neoprene and Low Temp Nitrile (Buna) are available.*
- Orifice Diameter
- See table above.
- Porting
- 1/8” OR 1/4” NPT
- Life Expectancy
- Millions of cycles, depending on application, lubrication, etc.
- Valve Weight
- 1.2 lb average
- Repair Packs
- See table above.
- Options
- Alternate body materials, voltages, elastomers available.* DIN Style Connector Part Number 20-198 or Part Number 20-19102
Series 20 Model 22 Magnetic Latching







Cv Flow Formulae
PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.
The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.
Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.
Liquid Flow
Gas Flow P2 > 53% of P1 (subsonic)
Gas Flow P2 < 53% of P1 (sonic)
DISCLAIMER: Gas flow is only an approximation using Cv.